A heat pump on the Eastern Shore spends most of its life in cooling. Then a front comes through, the thermostat flips to heat, and every neglected fault in the reversing valve, the defrost board, and the backup strips shows up on the same night. Repair has to understand both modes, because the homeowner experiences them as two different appliances and they are not.
Daphne subdivisions east of Highway 181, newer sections of Spanish Fort off SR-225, and the houses filling in around Foley and Loxley are full of heat pumps. Fairhope has a wider mix, with gas furnaces in older cottages and heat pumps in the subdivisions east of Greeno Road. Point Clear waterfront houses often have heat pumps working harder than they should because the coil is corroded and the house is large.
Cooling mode, which is most of the year
In cooling, a heat pump fails the same ways a straight-cool condenser fails. Capacitors, contactors, fan motors, dirty coils, low charge, compressors that overheat. The humidity load is the part national troubleshooting charts underweight. A system can make the thermostat and still leave a Fairhope house sticky if it short-cycles or if the blower is moving too much air across a coil that never gets cold enough to wring water out.
Salt on the outdoor coil raises head pressure all summer. That is a repair issue, not a cosmetic one. Fins that are intact get cleaned. Fins that are gone mean the coil is at the end of its life, and replacement is the straight answer.
Heating mode, which is when people get surprised
Defrost is the Baldwin County-specific failure. The outdoor coil ices in damp cold, the board should reverse the system briefly and melt it, and the strips should hold the house while that happens. A defrost board that never initiates, a sensor that is lying, or strips that do not stage on, produce a house that gets colder the longer the system runs. Homeowners hear the outdoor unit roaring and feel cool air and assume the thermostat is backwards. Sometimes the thermostat really is configured wrong. Often the refrigeration circuit is stuck in the wrong direction because the reversing valve did not shift.
Charge matters in both modes. A system that was “a little low” all summer may still cool on a mild day and then fail to heat when the outdoor temperature drops, because heating mode is less forgiving of a short charge. Gauges belong on that call. Guessing from the feel of the suction line does not.
What the estimate includes
The outdoor unit, the air handler, the thermostat configuration, the filter, the drain, and a run in the mode that failed. You get a price for the repair if a repair is the right move, and a straight comparison if the compressor or the coil means the system is finished. Heat pump installation is the page for a new system. Heating and furnace repair is the page if the house actually has a gas furnace and someone called it a heat pump out of habit.
Free estimate. No obligation. Tell us the town and which mode failed.
Published national ranges are on the AC repair cost page. They are not a Daphne quote.